LS02-1A71
|
liquid level sensors magnetic float 10mm mounting thread |
other connectors |
Avl |
RFQ |
3315172071
|
dry reed relay, spst, momentary, 0.008a (coil), 15vdc (coil), 113mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
MK25-1C90-5000W
|
reed relays 1 form c spdt atex push button |
reed relays |
Avl |
RFQ |
LP12-1A66-80U
|
dry reed relay, spst, momentary, 0.013a (coil), 12vdc (coil), 155mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
1924169114
|
dry reed relay, spst, momentary, 0.034a (coil), 24vdc (coil), 822mw (coil), 3a (contact), 10000vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
MK25-1A46-5000W
|
reed relays 1 form a spst-no atex push button |
reed relays |
Avl |
RFQ |
3205190251
|
dry reed relay, spdt, momentary, 0.025a (coil), 5vdc (coil), 125mw (coil), 0.5a (contact), 175vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
DIP05-1A75-11E
|
dry reed relay, spst, momentary, 0.014a (coil), 7.5vdc (coil), 50mw (coil), 0.5a (contact), 500vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
DIL05-2A31-20L
|
dry reed relay |
reed relay |
Avl |
RFQ |
DIP05-1C90-51E
|
dry reed relay, spdt, momentary, 0.034a (coil), 7.5vdc (coil), 125mw (coil), 0.5a (contact), 175vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
8824171600
|
dry reed relay, spst, momentary, 0.006a (coil), 24vdc (coil), 136mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
MRX05-1C21
|
reed relays ex-approved relays 1 form c, spdt, 5v |
reed relays |
Avl |
RFQ |
DIP05-1A72-13M
|
dry reed relay, spst, momentary, 0.014a (coil), 7.5vdc (coil), 50mw (coil), 1a (contact), 200vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
3312175071
|
dry reed relay |
reed relay |
Avl |
RFQ |
DIP24-1B72-19Q
|
dry reed relay, spst, momentary, 0.014a (coil), 30vdc (coil), 290mw (coil), 1a (contact), 200vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
NP-CL-1A81-9-213
|
dry reed relay, spst, momentary, 0.5a (contact), 90vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
HM24-1B83-150
|
dry reed relay, spst, momentary, 0.024a (coil), 24vdc (coil), 576mw (coil), 3a (contact), 7500vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
HM12-1A69-06
|
dry reed relay, spst, momentary, 0.08a (coil), 12vdc (coil), 960mw (coil), 3a (contact), 10000vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
DIP24-1A75-10A
|
dry reed relay, spst, momentary, 0.014a (coil), 30vdc (coil), 290mw (coil), 0.5a (contact), 500vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
DIL05-2A75-21L
|
dry reed relay |
reed relay |
Avl |
RFQ |
HF05-1A54-9
|
dry reed relay, spst, momentary, 0.125a (coil), 5vdc (coil), 625mw (coil), 1.5a (contact), 500vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
4205187075
|
dry reed relay, spst, momentary, 0.018a (coil), 5vdc (coil), 90mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
DIP15-1B72-19Q
|
dry reed relay, spst, momentary, 0.009a (coil), 20vdc (coil), 115mw (coil), 1a (contact), 200vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
RM05-4AS-4 2
|
dry reed relay |
reed relay |
Avl |
RFQ |
3312100074
|
dry reed relay, spst, momentary, 0.012a (coil), 12vdc (coil), 144mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
DIP15-1A75-10C
|
dry reed relay, spst, momentary, 0.009a (coil), 20vdc (coil), 115mw (coil), 0.5a (contact), 500vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
1305300030
|
dry reed relay |
reed relay |
Avl |
RFQ |
BT12-2A66
|
dry reed relay, dpst, momentary, 0.003a (coil), 12vdc (coil), 30mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
8506183152
|
dry reed relay |
reed relay |
Avl |
RFQ |
1305190553
|
dry reed relay |
reed relay |
Avl |
RFQ |
SIL12-1A31-72L
|
dry reed relay |
reed relay |
Avl |
RFQ |
BE24-2A66-P
|
dry reed relay, dpst, momentary, 0.017a (coil), 30vdc (coil), 1700mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
MRX12-1A21
|
dry reed relay, spst, momentary, 0.009a (coil), 12vdc (coil), 110mw (coil), 0.25a (contact), 100vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
DIP05-1C90-BV704
|
dry reed relay, spdt, momentary, 0.025a (coil), 5vdc (coil), 125mw (coil), 0.25a (contact), 175vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
3212172111
|
dry reed relay, spst, momentary, 0.012a (coil), 12vdc (coil), 144mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
DIL12-1C90-53L
|
dry reed relay |
reed relay |
Avl |
RFQ |
DIL05-2C90-63M
|
dry reed relay |
reed relay |
Avl |
RFQ |
291-9704
|
dry reed relay, spdt, momentary, 0.025a (coil), 5vdc (coil), 125mw (coil), 0.25a (contact), 175vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
DIP24-1A75-13M
|
dry reed relay, spst, momentary, 0.014a (coil), 30vdc (coil), 290mw (coil), 0.5a (contact), 500vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
3224190851
|
dry reed relay, spdt, momentary, 0.012a (coil), 24vdc (coil), 288mw (coil), 0.5a (contact), 175vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
HM05-1A83-02
|
dry reed relay, spst, momentary, 0.111a (coil), 5vdc (coil), 555mw (coil), 3a (contact), 7500vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
DIP05-1C96-51D
|
dry reed relay, spdt, momentary, 0.025a (coil), 5vdc (coil), 125mw (coil), 0.5a (contact), 175vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
HM12-1B69-06
|
dry reed relay, spst, momentary, 0.048a (coil), 12vdc (coil), 576mw (coil), 3a (contact), 10000vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
HM05-1B69-06
|
dry reed relay, spst, momentary, 0.111a (coil), 5vdc (coil), 555mw (coil), 3a (contact), 10000vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
3205196751
|
dry reed relay, spdt, momentary, 0.025a (coil), 5vdc (coil), 125mw (coil), 0.5a (contact), 175vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
BE24-2B66-M
|
dry reed relay, dpst, momentary, 0.01a (coil), 24vdc (coil), 276mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
BE05-1A66-V
|
dry reed relay, spst, momentary, 0.014a (coil), 5vdc (coil), 72mw (coil), 0.5a (contact), 180vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
1305001050
|
dry reed relay, spdt, momentary, 0.023a (coil), 5vdc (coil), 115mw (coil), 0.5a (contact), 175vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
9005185401
|
dry reed relay, spst, momentary, 0.063a (coil), 5vdc (coil), 315mw (coil), 1a (contact), 1000vdc (contact), surface mount-straight |
reed relay |
Avl |
RFQ |
3212172712
|
dry reed relay, spst, momentary, 0.012a (coil), 12vdc (coil), 144mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
HF12-1B54-5
|
dry reed relay, spst, momentary, 0.071a (coil), 12vdc (coil), 850mw (coil), 1.5a (contact), 500vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
8805171200
|
dry reed relay, spst, momentary, 0.014a (coil), 5vdc (coil), 72mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
HE24-1A83-150
|
dry reed relay, spst, momentary, 0.023a (coil), 24vdc (coil), 549mw (coil), 3a (contact), 7500vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
8824371200
|
dry reed relay, 3pst, momentary, 0.01a (coil), 24vdc (coil), 276mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
8805285100
|
dry reed relay, dpst, momentary, 0.071a (coil), 5vdc (coil), 357mw (coil), 1a (contact), 1000vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
3205172411
|
dry reed relay, spst, momentary, 0.005a (coil), 5vdc (coil), 25mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
8705121200
|
dry reed relay, spdt, momentary, 0.014a (coil), 5vdc (coil), 70mw (coil), 0.05a (contact), 100vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
BE12-1A66-M
|
dry reed relay, spst, momentary, 0.007a (coil), 16vdc (coil), 67mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
3305190171
|
dry reed relay |
reed relay |
Avl |
RFQ |
DIL24-1A66-10C
|
dry reed relay |
reed relay |
Avl |
RFQ |
RM05-6AS-4
|
electromechanical relay 6pst-no 0.5a 5vdc 185ohm surface mount |
other connectors |
Avl |
RFQ |
DIL05-2A72-21D
|
dry reed relay |
reed relay |
Avl |
RFQ |
DIL05-3A71-30L
|
dry reed relay |
reed relay |
Avl |
RFQ |
8524183003
|
dry reed relay, spst, momentary, 0.023a (coil), 24vdc (coil), 549mw (coil), 3a (contact), 7500vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
DIL-CL-1A81-9
|
electromechanical relay spst-no 0.5a 9ohm through hole |
other connectors |
Avl |
RFQ |
4212087078
|
dry reed relay, spst, momentary, 0.017a (coil), 12vdc (coil), 205mw (coil), 0.4a (contact), 200vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
1312175013
|
dry reed relay |
reed relay |
Avl |
RFQ |
8824271100
|
dry reed relay, dpst, momentary, 0.012a (coil), 24vdc (coil), 339mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
BE24-1A74
|
electromechanical relay spst-no 1a 24vdc 7.845kohm through hole |
other connectors |
Avl |
RFQ |
HM24-1A69-04
|
dry reed relay, spst, momentary, 0.04a (coil), 24vdc (coil), 960mw (coil), 3a (contact), 10000vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
1205100811
|
dry reed relay, spst, momentary, 0.022a (coil), 5vdc (coil), 109mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
3305172371
|
dry reed relay, spst, momentary, 0.01a (coil), 5vdc (coil), 50mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
MK01-B
|
sensor magnetic spst-no smd |
electromechanical swit |
Avl |
RFQ |
8824185200
|
dry reed relay, spst, momentary, 0.009a (coil), 24vdc (coil), 250mw (coil), 1a (contact), 1000vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
DIP15-1A72-11D
|
dry reed relay, spst, momentary, 0.009a (coil), 20vdc (coil), 115mw (coil), 1a (contact), 200vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
DIP24-2A72-21D
|
meder electronic (standex) reed relays 2 form a, spst-no 24v dip w/diode |
reed relays |
Avl |
RFQ |
1312002063
|
dry reed relay, dpdt, momentary, 0.016a (coil), 12vdc (coil), 211mw (coil), 0.25a (contact), 175vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
9605180022
|
dry reed relay, spst, momentary, 0.03a (coil), 5vdc (coil), 150mw (coil), 0.5a (contact), 170vdc (contact), surface mount-straight |
reed relay |
Avl |
RFQ |
DIP05-1C90-51D
|
dry reed relay, spdt, momentary, 0.034a (coil), 7.5vdc (coil), 125mw (coil), 0.5a (contact), 175vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
LP05-1A71-81W
|
dry reed relay, spst, momentary, 0.022a (coil), 5vdc (coil), 109mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
SIL05-1A85-76L3K
|
reed relay reed rely spst-no 5v sil1 inline hp 3k |
reed relay |
Avl |
RFQ |
LS02-1A71-PA500W
|
liquid level sensors magnetic float 10mm mounting thread |
other connectors |
Avl |
RFQ |
HE12-1A83-150
|
dry reed relay, spst, momentary, 0.046a (coil), 12vdc (coil), 554mw (coil), 3a (contact), 7500vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
KSK-1C90F-1520
|
switch reed 175vdc 10w axl |
electromechanical swit |
Avl |
RFQ |
DIL05-1C90-53L
|
dry reed relay |
reed relay |
Avl |
RFQ |
BE05-1E66-M
|
dry reed relay, spst, latched, 0.004a (coil), 7.5vdc (coil), 29mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
LI24-1A66
|
dry reed relay, spst, momentary, 0.007a (coil), 24vdc (coil), 159mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
DIL05-2C90-60L
|
dry reed relay |
reed relay |
Avl |
RFQ |
HE05-1A83-02
|
dry reed relay, spst, momentary, 0.1a (coil), 5vdc (coil), 500mw (coil), 3a (contact), 7500vdc (contact), through hole-straight mount |
reed relay |
Avl |
RFQ |
DIL24-1A71-12L
|
dry reed relay |
reed relay |
Avl |
RFQ |