If you need to request a quote for the Microwave Engineering Corporatio's TS641401 Waveguide Assembly, with corresponding NSN 5985000035344, we have got you covered. Simply provide us with the desired quantity for the part number TS641401 available with CAGE Code 06351 and FSC 5985 Antennas Waveguides and Related Equipment, targeted price, and order-fulfillment date, and our dedicated account manager will be in touch with you within 15 minutes.
To make the process even more convenient for you, you can email us your bill of materials (BOM) in an excel format to sales@asap-purchasing.com. So, don't hesitate to contact us today and let us help you meet your NSN part needs, including the TS641401 Waveguide Assembly.
NSN Information for Part Number TS641401 with NSN 5985-00-003-5344, 5985000035344
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5985-00-003-5344 Item Description: Waveguide Assembly | 5985 | 000035344 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
7 | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Ts641401 | 6 | 2 | 5 |
Characteristics Data of NSN 5985-00-003-5344, 5985000035344
MRC | Criteria | Characteristic |
---|---|---|
AHSF | FLANGE QUANTITY | 2 |
AHSY | FLANGE INSIDE HEIGHT | 0.503 INCHES MINIMUM ALL FLANGES AND 0.506 INCHES MAXIMUM ALL FLANGES |
AHSZ | FLANGE OUTSIDE WIDTH | 1.610 INCHES MINIMUM ALL FLANGES AND 1.640 INCHES MAXIMUM ALL FLANGES |
AHTD | FLANGE DEPTH | 0.422 INCHES MINIMUM ALL FLANGES AND 0.453 INCHES MAXIMUM ALL FLANGES |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.12 |
CQGM | MAXIMUM OPERATING PRESSURE | 20.0 POUNDS PER SQUARE INCH GAGE |
CRFH | WAVEGUIDE INSIDE WIDTH | 0.897 INCHES MINIMUM AND 0.903 INCHES MAXIMUM |
CSFC | WAVEGUIDE OUTSIDE HEIGHT | 0.497 INCHES MINIMUM AND 0.500 INCHES MAXIMUM |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE ALL FLANGES SINGLE CONNECTION FACILITY |
CTCJ | FLANGE STYLE | COVER TYPE ALL FLANGES |
MATT | MATERIAL | BERYLLIUM SINGLE TUBING SEGMENT |
AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |
AHSX | FLANGE INSIDE WIDTH | 1.003 INCHES MINIMUM ALL FLANGES AND 1.006 INCHES MAXIMUM ALL FLANGES |
AHTA | FLANGE OUTSIDE HEIGHT | 1.610 INCHES MINIMUM FIRST FLANGE |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.169 INCHES MINIMUM ALL FLANGES ALL CONNECTION FACILITIES AND 0.172 INCHES MAXIMUM ALL FLANGES ALL CONNECTION FACILITIES |
AHTX | INSERTION LOSS IN DECIBELS | 0.10 |
CQHN | WAVEGUIDE OUTSIDE WIDTH | 0.997 INCHES MINIMUM AND 1.003 INCHES MAXIMUM |
CRLB | WAVEGUIDE INSIDE HEIGHT | 0.397 INCHES MINIMUM AND 0.403 INCHES MAXIMUM |
CSPL | WAVEGUIDE LONGER OFFSET DISTANCE | 3.462 INCHES NOMINAL |
CWBG | WAVEGUIDE OFFSET DISTANCE | 1.649 INCHES NOMINAL |
FLEX | FLEXIBILITY | FLEXIBLE SINGLE TUBING SEGMENT |
STYL | STYLE DESIGNATOR | BEND TYPE |