Using the Request for Quote (RFQ) form provided on this page, you can request competitive procurement options on part number C56H502 with rapid responses always offered by our staff. To ensure that you locate and procure exactly what you need with ease, we list parts with as much information as we can. For example, part number C56H502 It is listed as Motor Alternating Current. component manufactured by Reliance Electric Company, specifically under CAGE Code 71956. It is also accompanied by the NSN 6105000046941 for ease of organization, the first digits of the NSN indicating that the part belongs to FSC 6105 Motors Electrical.
NSN Information for Part Number C56H502 with NSN 6105-00-004-6941, 6105000046941
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6105-00-004-6941 Item Description: Motor Alternating Current | 6105 | 000046941 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
C56h502 | C | 9 | 5 |
Characteristics Data of NSN 6105-00-004-6941, 6105000046941
MRC | Criteria | Characteristic |
---|---|---|
AAJU | OVERALL LENGTH | 11.000 INCHES |
ABRR | KEYWAY WIDTH | 0.187 INCHES NOMINAL SINGLE END |
ABWV | SHAFT DIAMETER | 0.625 INCHES NOMINAL SINGLE END |
ANPZ | INCLOSURE FEATURE | DRIPPROOF PROTECTED-15 DEG |
AXCP | WINDING TYPE | INDUCTION-SINGLE VALUE CAPACITOR SPLIT PHASE |
BFMF | COOLING METHOD | NATURAL CONVECTION VENTILATED |
BKPQ | INCLOSURE SPECIFICATION | NEMA |
BTBY | SHAFT END STYLE | FLAT KEYWAY SINGLE END |
CNMM | FRAME SIZE DESIGNATION | AD56 |
CWCS | LENGTH OF SHAFT FROM HOUSING | 1.875 INCHES SINGLE END |
CWDM | SHAFT CENTER TO MOUNTING SURFACE DISTANCE | 3.500 INCHES SINGLE END |
CWFX | ROTOR SPEED RATING IN RPM | 1800.0 SINGLE NO LOAD |
CWFY | NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.750 INCHES |
CWGL | CURRENT RATING IN AMPS | 8.000 FIRST MULTIPLE OR 4.000 SECOND MULTIPLE INPUT |
AAJT | OVERALL HEIGHT | 6.313 INCHES |
AAJV | OVERALL WIDTH | 5.625 INCHES |
ABRV | KEYWAY DEPTH | 0.093 INCHES NOMINAL SINGLE END |
AFYS | KEYWAY LENGTH | 1.250 INCHES NOMINAL SINGLE END |
AKPS | DUTY CYCLE | CONTINUOUS |
AXGY | MOUNTING METHOD | FIXED BASE |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 SLOT |
BKPB | CURRENT RATING METHOD | LOAD |
CBBL | FEATURES PROVIDED | THERMAL PROTECTIVE DEVICE AND HORIZONTAL MOUNTING POSITION AND VERTICAL MOUNTING POSITION |
CNXS | POWER RATING | 0.500 HORSEPOWER OUTPUT |
CWDT | NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.000 INCHES |
CWDY | TEMP RATING | 40.0 OPERATING DEG CELSIUS |
CWGQ | CONNECTION TYPE AND VOLTAGE RATING IN VOLTS | 115.0 LINE TO NEUTRAL FIRST MULTIPLE INPUT OR 230.0 LINE TO NEUTRAL SECOND MULTIPLE INPUT |
CWHZ | SHAFT END CHARACTERISTIC | A9 SINGLE STYLE SINGLE END |
FAAZ | PHASE | SINGLE INPUT |
FREQ | FREQUENCY IN HERTZ | 60.0 INPUT |