If you need to request a quote for the Tyco Electronics Corporation Div's MS63-84 3-32IN YELLOW Insulation Sleeving Electrical, with corresponding NSN 5970011838051, we have got you covered. Simply provide us with the desired quantity for the part number MS63-84 3-32IN YELLOW available with CAGE Code 06090 and FSC 5970 Electrical Insulators and Insulating Materials, targeted price, and order-fulfillment date, and our dedicated account manager will be in touch with you within 15 minutes.
To make the process even more convenient for you, you can email us your bill of materials (BOM) in an excel format to sales@asap-purchasing.com. So, don't hesitate to contact us today and let us help you meet your NSN part needs, including the MS63-84 3-32IN YELLOW Insulation Sleeving Electrical.
NSN Information for Part Number MS63-84 3-32IN YELLOW with NSN 5970-01-183-8051, 5970011838051
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5970-01-183-8051 Item Description: INSULATION SLEEVING,ELECTRICAL | 5970 | 011838051 | P | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
MS63-84 3/32IN YELLOW | 3 | 2 | 5 |
Characteristics Data of NSN 5970-01-183-8051, 5970011838051
MRC | Criteria | Characteristic |
---|---|---|
HUES | COLOR | YELLOW |
STYL | STYLE DESIGNATOR | SHRINKABLE |
AGAU | HEAT SHRINKAGE RATING IN PERCENT | 50.0 |
ABHP | OVERALL LENGTH | 200.000 FEET MINIMUM |
ABJH | TEMP RATING | -55.0 DEG CELSIUS AND 135.0 DEG CELSIUS |
AFZL | EXPANDED INSIDE DIAMETER | 0.093 INCHES NOMINAL |
CQBC | MINIMUM TENSILE STRENGTH | 1500 POUNDS PER SQUARE INCH |
AFZM | RECOVERED INSIDE DIAMETER | 0.046 INCHES NOMINAL |
AFZN | RECOVERED WALL THICKNESS | 0.020 INCHES NOMINAL |
MATT | MATERIAL | PLASTIC POLYOLEFIN |
MATL | MATERIAL | PLASTIC, POLYOLEFIN |
UKBG | DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS | 500.0 VOLTS PER MIL /0.001 INCH/ |
FLEX | FLEXIBILITY | FLEXIBLE |