MRC | Criteria | Characteristic |
---|
ABTD | MOUNTING SLOT WIDTH | 0.187 INCHES NOMINAL |
ADAT | BODY WIDTH | 12.750 INCHES NOMINAL |
ADTV | CASE MATERIAL | METAL |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.375 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.500 INCHES NOMINAL |
AEGJ | SWITCH CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROW |
AKPX | POLE QUANTITY | 3 |
CBBL | FEATURES PROVIDED | ADJUSTABLE TRIP RELEASE |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 600.0 AC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
CPRP | ULTIMATE TRIP TIME PER POLE IN SECONDS | 56.000 NOMINAL ALL LOCATIONS |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 ROTARY |
CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE, TWO, AND THREE LINKED |
CPRZ | AUXILIARY SWITCH FUNCTION AND QUANTITY | 12 ALARM |
CPSF | ADJUSTABLE TRIP SETTING CURRENT RANGE PER POLE IN AMPS | +280.0/+460.0 AC ALL LOCATIONS AND +1750.0/+5250.0 AC ALL LOCATIONS |
CQTL | RESET ACTUATOR VOLTAGE RATING AND TYPE IN VOLTS | 208.0 AC |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 75.000 MINIMUM AT 100 PCT ALL LOCATIONS AND 1000.000 MAXIMUM AT 100 PCT ALL LOCATIONS AND 56.000 MINIMUM AT 150 PCT ALL LOCATIONS AND 200.000 MAXIMUM AT 150 PCT ALL LOCATIONS AND 46.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 300.000 MAXIMUM A |
CSSX | SWITCH CURRENT RATING AND TYPE IN AMPS | 12.0 AC AND 9.0 DC |
FEAT | SPECIAL FEATURES | LONG DELAY PICKUP,LONG TIME DELAYBAND,INSTANTANEOUS PICKUP SETTINGS ADJUSTABLE. |
AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
ADAQ | BODY LENGTH | 17.562 INCHES NOMINAL |
ADAU | BODY HEIGHT | 17.000 INCHES NOMINAL |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 3.625 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 11.625 INCHES NOMINAL |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 10.562 INCHES NOMINAL |
AJEC | BOSS HEIGHT | 0.375 INCHES NOMINAL |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 SLOT AND 4 UNTHREADED HOLE |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 600.0 AMPERES AC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 3500.0 AC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS ALL LOCATIONS AND TIME DELAY ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 150.0 ALL LOCATIONS |
CPRQ | RESET METHOD | ELECTRIC |
CPRW | ACTUATOR FUNCTION | RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SHUNT TRIP ALL LOCATIONS |
CRTK | SWITCH TERMINAL TYPE | THREADED STUD |
CSWP | SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 208.0 AC AND 120.0 DC |
FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
TTQY | TERMINAL TYPE AND QUANTITY | 6 BUS BAR |