Using the Request for Quote (RFQ) form provided on this page, you can request competitive procurement options on part number D52U1 with rapid responses always offered by our staff. To ensure that you locate and procure exactly what you need with ease, we list parts with as much information as we can. For example, part number D52U1 It is listed as Attenuator Fixed. component manufactured by Alliant Techsystems Operations Llc, specifically under CAGE Code 06424. It is also accompanied by the NSN 5985001313417 for ease of organization, the first digits of the NSN indicating that the part belongs to FSC 5985 Antennas Waveguides and Related Equipment.
NSN Information for Part Number D52U1 with NSN 5985-00-131-3417, 5985001313417
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5985-00-131-3417 Item Description: Attenuator Fixed | 5985 | 001313417 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
D52u1 | 6 | 9 | 5 |
Characteristics Data of NSN 5985-00-131-3417, 5985001313417
MRC | Criteria | Characteristic |
---|---|---|
AAFS | APPLICATION DESIGN | TRANSMISSION LINE |
AAFZ | BODY MATERIAL | ANY ACCEPTABLE |
ABHP | OVERALL LENGTH | 1.286 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0.531 INCHES NOMINAL |
AHTY | INPUT IMPEDANCE RATING IN OHMS | 50.0 |
AHUC | COAXIAL CONNECTOR SERIES DESIGNATION | OSM |
BBHS | TERMINAL TYPE AND QUANTITY | 3 CONNECTOR |
TEST | TEST DATA DOCUMENT | 06424-2605484 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAW |
AAQL | BODY STYLE | RECTANGULAR, TERMINAL/TERMINALS ON OPPOSITE SURFACES |
ABKW | OVERALL HEIGHT | 0.469 INCHES MINIMUM AND 0.797 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 0.562 INCHES NOMINAL |
AHTZ | OUTPUT IMPEDANCE RATING IN OHMS | 50.0 |
AJDB | POWER RATING | 5.0 WATTS AVERAGE |
AJDK | RF SIGNAL ATTENUATION IN DECIBELS | 20.0 |
ASYN | ATTENUATION ACCURACY IN DECIBELS | 0.80/+0.80 |
AXGY | MOUNTING METHOD | TERMINAL |
BNGR | FREQUENCY RANGE | 15.800 GIGAHERTZ MINIMUM AND 17.300 GIGAHERTZ MAXIMUM |