Using the Request for Quote (RFQ) form provided on this page, you can request competitive procurement options on part number X22-301-2-26 5 with rapid responses always offered by our staff. To ensure that you locate and procure exactly what you need with ease, we list parts with as much information as we can. For example, part number X22-301-2-26 5 It is listed as Relay Electromagnetic. component manufactured by Bofors Ab, specifically under CAGE Code S3715. It is also accompanied by the NSN 5945012084943 for ease of organization, the first digits of the NSN indicating that the part belongs to FSC 5945 Relays and Solenoids.
NSN Information for Part Number X22-301-2-26 5 with NSN 5945-01-208-4943, 5945012084943
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-01-208-4943 Item Description: Relay Electromagnetic | 5945 | 012084943 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
X22-301-2-26 5 | B | 1 | C | 9 |
Characteristics Data of NSN 5945-01-208-4943, 5945012084943
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 1.320 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.062 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 1.078 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
ABMK | OVERALL WIDTH | 0.410 INCHES MAXIMUM |
ADTV | CASE MATERIAL | METAL |
AKDX | WINDING QUANTITY | 1 |
APCN | COIL QUANTITY | 1 |
APNP | DUTY TYPE | CONTINUOUS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 SLOTTED HOLE SINGLE MOUNTING FACILITY |
CBBL | FEATURES PROVIDED | POLARIZED |
CBME | CUBIC MEASURE | 0.334 CUBIC INCHES |
CQYJ | MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 300.0 MILLIAMPERES AC RESISTIVE LOAD AND 2.0 AMPERES DC RESISTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
TTQY | TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |
ABKW | OVERALL HEIGHT | 0.617 INCHES MAXIMUM |
ABTD | MOUNTING SLOT WIDTH | 0.120 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
APNA | WINDING DC RESISTANCE RATING | 700.0 OHMS NOMINAL SINGLE WINDING |
APNQ | ARC QUENCHING METHOD | AIR |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CRXH | TIME DELAY | 0.004 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME |
FEAT | SPECIAL FEATURES | FAILURE RATE LEVEL 0.1 PERCENT |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-39016 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTI |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-39016/6 GOVERNMENT SPECIFICATION |