Using the Request for Quote (RFQ) form provided on this page, you can request competitive procurement options on part number 452-1420-9 with rapid responses always offered by our staff. To ensure that you locate and procure exactly what you need with ease, we list parts with as much information as we can. For example, part number 452-1420-9 It is listed as Circuit Breaker. component manufactured by Boonton Electronics Corporation, specifically under CAGE Code 04901. It is also accompanied by the NSN 5925002577066 for ease of organization, the first digits of the NSN indicating that the part belongs to FSC 5925 Circuit Breakers.
NSN Information for Part Number 452-1420-9 with NSN 5925-00-257-7066, 5925002577066
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-00-257-7066 Item Description: CIRCUIT BREAKER | 5925 | 002577066 | P | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
452-1420-9 | 5 | 2 | 3 |
Characteristics Data of NSN 5925-00-257-7066, 5925002577066
MRC | Criteria | Characteristic |
---|---|---|
ABMK | OVERALL WIDTH | 0.750 INCHES NOMINAL |
AKPX | POLE QUANTITY | 1 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 500.0 MILLIAMPERES AC SINGLE LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
CPRJ | TRIP RELEASE METHOD | MAGNETIC SINGLE LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 150.0 SINGLE LOCATION |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | MOISTURE RESISTANT AND SHOCKPROOF AND VIBRATIONPROOF |
THSD | THREAD SERIES DESIGNATOR | UNC |
ABHP | OVERALL LENGTH | 2.500 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 3.172 INCHES NOMINAL |
ADTV | CASE MATERIAL | PLASTIC |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 125.0 AC SINGLE LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 2000.0 AC SINGLE LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
CPRQ | RESET METHOD | AUTOMATIC |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 6.000 MINIMUM AT 125 PCT SINGLE LOCATION AND 22.000 MAXIMUM AT 125 PCT SINGLE LOCATION AND 2.500 MINIMUM AT 200 PCT SINGLE LOCATION AND 7.500 MAXIMUM AT 200 PCT SINGLE LOCATION AND 0.800 MINIMUM AT 300 PCT SINGLE LOCATION AND 2.500 MAXIMUM |
FREQ | FREQUENCY IN HERTZ | 60.0 SINGLE LOCATION |
TTQY | TERMINAL TYPE AND QUANTITY | 2 THREADED STUD |