Using the Request for Quote (RFQ) form provided on this page, you can request competitive procurement options on part number GP8000-42 with rapid responses always offered by our staff. To ensure that you locate and procure exactly what you need with ease, we list parts with as much information as we can. For example, part number GP8000-42 It is listed as Switch Pressure. component manufactured by Carleton Life Support Systems In, specifically under CAGE Code 99251. It is also accompanied by the NSN 5930007364085 for ease of organization, the first digits of the NSN indicating that the part belongs to FSC 5930 Switches.
NSN Information for Part Number GP8000-42 with NSN 5930-00-736-4085, 5930007364085
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-736-4085 Item Description: Switch Pressure | 5930 | 007364085 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Gp8000-42 | 2 | 2 | 5 |
Characteristics Data of NSN 5930-00-736-4085, 5930007364085
MRC | Criteria | Characteristic |
---|---|---|
ABKW | OVERALL HEIGHT | 2.620 INCHES NOMINAL |
ABPM | BODY DIAMETER | 2.625 INCHES NOMINAL |
AJZC | PRESSURE SWITCH TYPE | GAGE |
CMLP | THREAD QUANTITY PER INCH | 20 SINGLE PRESSURE CONNECTION |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CQJX | NOMINAL THREAD SIZE | 0.4375 INCHES SINGLE PRESSURE CONNECTION |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
CTHF | CONTACT LOAD CURRENT RATING | 2.5 AMPERES RESISTIVE LOAD SINGLE VOLTAGE |
CTYX | CONTACT STIMULUS RATING | 7.50 ACTUATION POINT NOMINAL POUNDS PER SQUARE INCH GAGE AND 5.50 DEACTUATION POINT NOMINAL POUNDS PER SQUARE INCH GAGE |
CTZL | PRESSURE CONNECTOR TYPE | PLAIN, THREADED INTERNAL SINGLE CONNECTION |
AAJD | THREAD CLASS | 3B SINGLE PRESSURE CONNECTION |
ABHP | OVERALL LENGTH | 3.484 INCHES NOMINAL |
ADAQ | BODY LENGTH | 2.060 INCHES NOMINAL |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 3.000 INCHES NOMINAL |
AWTN | OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 260.0 DEG FAHRENHEIT MAXIMUM |
AXGY | MOUNTING METHOD | BRACKET |
CQJB | PROOF PRESSURE | 120.00 POUNDS PER SQUARE INCH |
CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
CSCC | SENSING ELEMENT BURST PRESSURE | 180.00 POUNDS PER SQUARE INCH |
CSCF | TERMINAL TYPE | CONNECTOR, RECEPTACLE |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 30.0 DC AT SEA LEVEL SINGLE VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
STYL | STYLE DESIGNATOR | CYLINDRICAL W/MOUNTING LUGS |
THSD | THREAD SERIES DESIGNATOR | UNF SINGLE PRESSURE CONNECTION |