Using the Request for Quote (RFQ) form provided on this page, you can request competitive procurement options on part number AB2-B0-34-615-5D1-C with rapid responses always offered by our staff. To ensure that you locate and procure exactly what you need with ease, we list parts with as much information as we can. For example, part number AB2-B0-34-615-5D1-C It is listed as Circuit Breaker. component manufactured by Carling Technologies Inc, specifically under CAGE Code 73559. It is also accompanied by the NSN 5925015914542 for ease of organization, the first digits of the NSN indicating that the part belongs to FSC 5925 Circuit Breakers.
NSN Information for Part Number AB2-B0-34-615-5D1-C with NSN 5925-01-591-4542, 5925015914542
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-591-4542 Item Description: Circuit Breaker | 5925 | 015914542 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Ab2-B0-34-615-5d1-C | 5 | 2 | 3 |
Characteristics Data of NSN 5925-01-591-4542, 5925015914542
MRC | Criteria | Characteristic |
---|---|---|
ADAQ | BODY LENGTH | 2.000 INCHES NOMINAL |
CPRQ | RESET METHOD | MANUAL |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 80.0 DC ALL LOCATIONS |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.750 INCHES NOMINAL |
ABXD | BUSHING LENGTH | 0.130 NOMINAL INCHES |
AGAV | END ITEM IDENTIFICATION | MISC PARTS LIST FOR LCU 1617 |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
AKPX | POLE QUANTITY | 2 |
ADAT | BODY WIDTH | 1.515 INCHES NOMINAL |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 15.0 AMPERES DC ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC ALL LOCATIONS |
TTQY | TERMINAL TYPE AND QUANTITY | 4 SCREW |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 7500.0 DC ALL LOCATIONS |
ADTV | CASE MATERIAL | PLASTIC |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.032 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.660 INCHES NOMINAL |
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.558 INCHES NOMINAL |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
FEAT | SPECIAL FEATURES | TERMINALS ARE BUS TYPE, 10-32 SCREWS; 50/60 HZ; MEDIUM DELAY; BLACK ACTUATOR WITH LEGEND ON-OFF IN WHITE; UL RECOGNIZED AND CSA ACCEPTED |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO |