Using the Request for Quote (RFQ) form provided on this page, you can request competitive procurement options on part number 3SBC1393A2 with rapid responses always offered by our staff. To ensure that you locate and procure exactly what you need with ease, we list parts with as much information as we can. For example, part number 3SBC1393A2 It is listed as Relay Electromagnetic component manufactured by Communications Instruments Inc, specifically under CAGE Code 1DUQ5. It is also accompanied by the NSN 5945005644028 for ease of organization, the first digits of the NSN indicating that the part belongs to FSC 5945 Relays and Solenoids.
NSN Information for Part Number 3SBC1393A2 with NSN 5945-00-564-4028, 5945005644028
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-00-564-4028 Item Description: Relay Electromagnetic | 5945 | 005644028 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
3sbc1393a2 | 2 | 9 | 3 |
Characteristics Data of NSN 5945-00-564-4028, 5945005644028
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 1.062 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 0.312 INCHES MAXIMUM |
ABTD | MOUNTING SLOT WIDTH | 0.281 INCHES NOMINAL SINGLE MOUNTING FACILITY |
AKDX | WINDING QUANTITY | 1 |
APNP | DUTY TYPE | CONTINUOUS |
CQYJ | MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
CRXH | TIME DELAY | 0.004 SECONDS MAXIMUM FIXED RELEASE TIME |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 500.0 MILLIAMPERES AC RESISTIVE LOAD AND 2.0 AMPERES DC RESISTIVE LOAD |
TTQY | TERMINAL TYPE AND QUANTITY | 4 PIN ALL FUNCTIONS |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.156 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABMK | OVERALL WIDTH | 0.512 INCHES MAXIMUM |
ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF |
APCN | COIL QUANTITY | 1 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 SLOTTED HOLE SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |