Using the Request for Quote (RFQ) form provided on this page, you can request competitive procurement options on part number 604G11-36S with rapid responses always offered by our staff. To ensure that you locate and procure exactly what you need with ease, we list parts with as much information as we can. For example, part number 604G11-36S It is listed as Switch Pressure. component manufactured by Custom Control Sensors Inc, specifically under CAGE Code 09049. It is also accompanied by the NSN 5930000850602 for ease of organization, the first digits of the NSN indicating that the part belongs to FSC 5930 Switches.
NSN Information for Part Number 604G11-36S with NSN 5930-00-085-0602, 5930000850602
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-085-0602 Item Description: Switch Pressure | 5930 | 000850602 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
604g11-36s | 2 | 2 | 3 |
Characteristics Data of NSN 5930-00-085-0602, 5930000850602
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 6.230 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 4.750 INCHES NOMINAL |
AFDV | LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 3.100 INCHES NOMINAL |
CBBL | FEATURES PROVIDED | ELECTRICAL ACCESS PORT |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CQYJ | MOUNTING FACILITY PATTERN | FOUR POSITION RECTANGULAR |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CTYM | CONTACT ADJUSTMENT RANGE | +20.00/+100.00 ACTUATION POINT POUNDS PER SQUARE INCH AND +20.00 TO 100.00 DEACTUATION POINT POUNDS PER SQUARE INCH |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
THSD | THREAD SERIES DESIGNATOR | NPT SINGLE PRESSURE CONNECTION |
ABKW | OVERALL HEIGHT | 2.710 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.265 INCHES NOMINAL |
AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 4.250 INCHES NOMINAL |
AJZC | PRESSURE SWITCH TYPE | GAGE |
AWTN | OPERATING TEMP RATING | 30.0 DEG FAHRENHEIT MINIMUM AND 160.0 DEG FAHRENHEIT MAXIMUM |
AXGY | MOUNTING METHOD | FLANGE AND UNTHREADED HOLE |
CMLP | THREAD QUANTITY PER INCH | 18 SINGLE PRESSURE CONNECTION |
CQJB | PROOF PRESSURE | 4500.00 POUNDS PER SQUARE INCH |
CQJX | NOMINAL THREAD SIZE | 0.250 INCHES SINGLE PRESSURE CONNECTION |
CSCF | TERMINAL TYPE | SCREW |
CTHF | CONTACT LOAD CURRENT RATING | 15.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE |
CTYS | CONTACT ADJUSTMENT TYPE | INTERNAL DEACTUATION POINT HEX NUT AND INTERNAL ACTUATION POINT HEX NUT |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 480.0 AC AT SEA LEVEL FIRST VOLTAGE |
CTZL | PRESSURE CONNECTOR TYPE | PLAIN, THREADED INTERNAL SINGLE CONNECTION |
STYL | STYLE DESIGNATOR | RECTANGULAR W/BRACKET |