Using the Request for Quote (RFQ) form provided on this page, you can request competitive procurement options on part number ADP4733P1 with rapid responses always offered by our staff. To ensure that you locate and procure exactly what you need with ease, we list parts with as much information as we can. For example, part number ADP4733P1 It is listed as Switch Thermostatic. component manufactured by Dielectric Laboratories Inc, specifically under CAGE Code 72634. It is also accompanied by the NSN 5930005814064 for ease of organization, the first digits of the NSN indicating that the part belongs to FSC 5930 Switches.
NSN Information for Part Number ADP4733P1 with NSN 5930-00-581-4064, 5930005814064
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-581-4064 Item Description: Switch Thermostatic | 5930 | 005814064 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Adp4733p1 | 6 | 9 | 3 |
Characteristics Data of NSN 5930-00-581-4064, 5930005814064
MRC | Criteria | Characteristic |
---|---|---|
ABPM | BODY DIAMETER | 0.618 INCHES MINIMUM AND 0.625 INCHES MAXIMUM |
AXGY | MOUNTING METHOD | IMMERSION WELL |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
CSCF | TERMINAL TYPE | WIRE LEAD |
FEAT | SPECIAL FEATURES | ONE 1/4 IN.-14 THD BUSHING 0.750 IN. LG |
ABHP | OVERALL LENGTH | 5.250 INCHES NOMINAL |
AKBY | TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
ASDB | WIDTH ACROSS FLATS | 1.000 INCHES NOMINAL |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CTHF | CONTACT LOAD CURRENT RATING | 10.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE, PRESET AND ACTUATION POINT ADJUSTABLE, PRESET |
CTYM | CONTACT ADJUSTMENT RANGE | -100.00/+600.00 ACTUATION POINT DEGREES FAHRENHEIT AND -100.00/+600.00 DEACTUATION POINT DEGREES FAHRENHEIT |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL DEACTUATION POINT HEX NUT AND EXTERNAL ACTUATION POINT HEX NUT |
CTYX | CONTACT STIMULUS RATING | 510.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 500.00 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL SECOND VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
STYL | STYLE DESIGNATOR | CYLINDRICAL |