Using the Request for Quote (RFQ) form provided on this page, you can request competitive procurement options on part number 8345-B03A-V3M1-DB1A1B-125A with rapid responses always offered by our staff. To ensure that you locate and procure exactly what you need with ease, we list parts with as much information as we can. For example, part number 8345-B03A-V3M1-DB1A1B-125A It is listed as Circuit Breaker component manufactured by E T A Circuit Breakers, specifically under CAGE Code 3D8G0. It is also accompanied by the NSN 5925015659698 for ease of organization, the first digits of the NSN indicating that the part belongs to FSC 5925 Circuit Breakers.
NSN Information for Part Number 8345-B03A-V3M1-DB1A1B-125A with NSN 5925-01-565-9698, 5925015659698
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-565-9698 Item Description: Circuit Breaker | 5925 | 015659698 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
8345-B03a-V3m1-Db1a1b-125a | 5 | 2 | 3 |
Characteristics Data of NSN 5925-01-565-9698, 5925015659698
MRC | Criteria | Characteristic |
---|---|---|
AGAV | END ITEM IDENTIFICATION | BOAT, UNMANNED, 40 FT 4OUC0701. |
TTQY | TERMINAL TYPE AND QUANTITY | 2 THREADED STUD |
AKPX | POLE QUANTITY | 3 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 125.0 AMPERES AC SINGLE LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 80.0 DC SINGLE LOCATION |
FEAT | SPECIAL FEATURES | FLANGE MOUNTING, WITH RECTANGULAR APERTURE WITH MOUNTING NUT 6-32UNC.WIRHOUT BARRIER. THREE POLE PROTECTED. ALL POLES WITH STANDARD TOGGLE. STUD TERMINALS 1/4-2UNC-3A<125A. TERMINAL HARDWARE:SPLIT WASHER WITH NUT. MEDIUM DELAY DC.BLACK ACTU |