Using the Request for Quote (RFQ) form provided on this page, you can request competitive procurement options on part number MM2RD3LC07DA202 with rapid responses always offered by our staff. To ensure that you locate and procure exactly what you need with ease, we list parts with as much information as we can. For example, part number MM2RD3LC07DA202 It is listed as Circuit Breaker. component manufactured by Eaton Corp Controls Div, specifically under CAGE Code 96170. It is also accompanied by the NSN 5925013773076 for ease of organization, the first digits of the NSN indicating that the part belongs to FSC 5925 Circuit Breakers.
NSN Information for Part Number MM2RD3LC07DA202 with NSN 5925-01-377-3076, 5925013773076
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-377-3076 Item Description: Circuit Breaker | 5925 | 013773076 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Mm2rd3lc07da202 | 5 | 2 | 3 |
Characteristics Data of NSN 5925-01-377-3076, 5925013773076
MRC | Criteria | Characteristic |
---|---|---|
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.062 INCHES NOMINAL |
THSD | THREAD SERIES DESIGNATOR | UNC |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 135.0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
ADAQ | BODY LENGTH | 2.500 INCHES NOMINAL |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.750 INCHES NOMINAL |
ADTV | CASE MATERIAL | PLASTIC |
AGAV | END ITEM IDENTIFICATION | PANEL, AC DISTB., P/N 2009-002-01 USED ONBOARD 47 FT MLB COAST GUARD VESSELS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE |
SR-5 | DESIGN CONTROL REFERENCE | MM2RD3LC07DA202 |
AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC AND 65.0 DC ALL LOCATIONS |
SR-5 | MANUFACTURERS CODE | 96170 |
TTQY | TERMINAL TYPE AND QUANTITY | 4 THREADED STUD |
CPRW | ACTUATOR FUNCTION | RESET |
SR-5 | THE MANUFACTURERS DATA | |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.481 INCHES NOMINAL |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.938 INCHES NOMINAL |
AKPX | POLE QUANTITY | 2 |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
ADAT | BODY WIDTH | 1.500 INCHES NOMINAL |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 20.0 AMPERES AC ALL LOCATIONS AND 20.0 AMPERES DC ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC ALL LOCATIONS |
CMLP | THREAD QUANTITY PER INCH | 32 |
FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 1.938 INCHES NOMINAL |
CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS ALL LOCATIONS |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
AJEC | BOSS HEIGHT | 0.140 INCHES NOMINAL |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC ALL LOCATIONS AND 5000.0 DC ALL LOCATIONS |