Using the Request for Quote (RFQ) form provided on this page, you can request competitive procurement options on part number 23002970-9 with rapid responses always offered by our staff. To ensure that you locate and procure exactly what you need with ease, we list parts with as much information as we can. For example, part number 23002970-9 It is listed as Resistor Fixed Wire Wound Nonind. component manufactured by Equipment And Supply Inc, specifically under CAGE Code 53327. It is also accompanied by the NSN 5905002849507 for ease of organization, the first digits of the NSN indicating that the part belongs to FSC 5905 Resistors.
NSN Information for Part Number 23002970-9 with NSN 5905-00-284-9507, 5905002849507
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5905-00-284-9507 Item Description: Resistor Fixed Wire Wound Nonind | 5905 | 002849507 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
23002970-9 | 5 | 1 | C | A |
Characteristics Data of NSN 5905-00-284-9507, 5905002849507
MRC | Criteria | Characteristic |
---|---|---|
AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 125.0 |
AARG | RELIABILITY INDICATOR | ESTABLISHED |
ABPM | BODY DIAMETER | 0.250 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0.750 INCHES NOMINAL |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-39005 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTI |
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -10.0/+10.0 |
AAPP | ELECTRICAL RESISTANCE | 34.000 KILOHMS |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -1.000/+1.000 |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 145.0 |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -65.0/+145.0 |
AAQZ | INCLOSURE METHOD | ENCAPSULATED |
AARB | TERMINAL TYPE | WIRE LEAD |
AARH | RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.010 |
AEFB | POWER DISSIPATION RATING IN WATTS | 0.250 FREE AIR |
STYL | STYLE DESIGNATOR | AXIAL TERMINAL EACH END |