Using the Request for Quote (RFQ) form provided on this page, you can request competitive procurement options on part number BF72 with rapid responses always offered by our staff. To ensure that you locate and procure exactly what you need with ease, we list parts with as much information as we can. For example, part number BF72 It is listed as Transformer Power. component manufactured by Ferranti Electric Inc, specifically under CAGE Code 22119. It is also accompanied by the NSN 5950008486318 for ease of organization, the first digits of the NSN indicating that the part belongs to FSC 5950 Coils and Transformers.
NSN Information for Part Number BF72 with NSN 5950-00-848-6318, 5950008486318
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-848-6318 Item Description: Transformer Power | 5950 | 008486318 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Bf72 | 6 | 9 | 5 |
Characteristics Data of NSN 5950-00-848-6318, 5950008486318
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTB | MOUNTING HOLE DIAMETER | 0.187 INCHES NOMINAL SINGLE GROUP |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 4.375 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 250.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT ALL SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
ADAT | BODY WIDTH | 3.000 INCHES NOMINAL |
ADAU | BODY HEIGHT | 3.000 INCHES NOMINAL |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT |
TTQY | TERMINAL TYPE AND QUANTITY | 9 WIRE LEAD |