Using the Request for Quote (RFQ) form provided on this page, you can request competitive procurement options on part number 19936 with rapid responses always offered by our staff. To ensure that you locate and procure exactly what you need with ease, we list parts with as much information as we can. For example, part number 19936 It is listed as Reactor. component manufactured by Freed Transformer Co, specifically under CAGE Code 73386. It is also accompanied by the NSN 5950006481900 for ease of organization, the first digits of the NSN indicating that the part belongs to FSC 5950 Coils and Transformers.
NSN Information for Part Number 19936 with NSN 5950-00-648-1900, 5950006481900
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-648-1900 Item Description: Reactor | 5950 | 006481900 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
19936 | 6 | 2 | 3 |
Characteristics Data of NSN 5950-00-648-1900, 5950006481900
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.299 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACYV | INDUCTANCE RATING | 2.00 HENRY NOMINAL SINGLE COMPONENT SINGLE WINDING |
ADAT | BODY WIDTH | 1.625 INCHES NOMINAL |
ADAU | BODY HEIGHT | 3.000 INCHES NOMINAL |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 125.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT SINGLE WINDING |
TTQY | TERMINAL TYPE AND QUANTITY | 2 SOLDER STUD |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.065 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACYF | INDUCTANCE TYPE | FIXED |
ADAQ | BODY LENGTH | 1.875 INCHES NOMINAL |
AKDX | WINDING QUANTITY | 1 SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT SINGLE WINDING |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE GROUP |
CRGS | DC RESISTANCE RATING IN OHMS | 41.000 SINGLE COMPONENT SINGLE WINDING |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |