Using the Request for Quote (RFQ) form provided on this page, you can request competitive procurement options on part number FD1009DD with rapid responses always offered by our staff. To ensure that you locate and procure exactly what you need with ease, we list parts with as much information as we can. For example, part number FD1009DD It is listed as Transformer Power. component manufactured by Gte Communication Systems Corp, specifically under CAGE Code 04773. It is also accompanied by the NSN 5950001031582 for ease of organization, the first digits of the NSN indicating that the part belongs to FSC 5950 Coils and Transformers.
NSN Information for Part Number FD1009DD with NSN 5950-00-103-1582, 5950001031582
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-103-1582 Item Description: Transformer Power | 5950 | 001031582 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Fd1009dd | 6 | 9 | 3 |
Characteristics Data of NSN 5950-00-103-1582, 5950001031582
MRC | Criteria | Characteristic |
---|---|---|
ABTD | MOUNTING SLOT WIDTH | 0.219 INCHES NOMINAL SINGLE GROUP |
ACZB | FREQUENCY RATING | 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ADAQ | BODY LENGTH | 3.156 INCHES MAXIMUM |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 2.469 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.531 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 625.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT ALL PRIMARY |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAT | BODY WIDTH | 7.125 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 3.000 INCHES MAXIMUM |
AKPV | MOUNTING FACILITY QUANTITY | 3 SINGLE GROUP |
AXGY | MOUNTING METHOD | SLOT SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 120.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY |
TTQY | TERMINAL TYPE AND QUANTITY | 8 TAB, SOLDER LUG |