Using the Request for Quote (RFQ) form provided on this page, you can request competitive procurement options on part number 7012L8DN with rapid responses always offered by our staff. To ensure that you locate and procure exactly what you need with ease, we list parts with as much information as we can. For example, part number 7012L8DN It is listed as Relay Electromagnetic. component manufactured by Harvard Industries, specifically under CAGE Code 72962. It is also accompanied by the NSN 5945010097713 for ease of organization, the first digits of the NSN indicating that the part belongs to FSC 5945 Relays and Solenoids.
NSN Information for Part Number 7012L8DN with NSN 5945-01-009-7713, 5945010097713
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-01-009-7713 Item Description: Relay Electromagnetic | 5945 | 010097713 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
7012l8dn | 1 | 2 | 3 |
Characteristics Data of NSN 5945-01-009-7713, 5945010097713
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 3.250 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 4.520 INCHES MAXIMUM |
ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.199 INCHES NOMINAL FIRST MOUNTING FACILITY |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJSS | FREQUENCY IN HERTZ | 60.0 NOMINAL |
APCN | COIL QUANTITY | 1 |
APNQ | ARC QUENCHING METHOD | AIR |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SECOND MOUNTING FACILITY |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 240.0 AC AND 30.0 DC |
CWJB | ENERGIZING ELEMENT POWER RATING | 8.0 WATTS |
TTQY | TERMINAL TYPE AND QUANTITY | 8 SCREW ALL FUNCTIONS |
AAJD | THREAD CLASS | 2B SECOND MOUNTING FACILITY |
AAJF | THREAD DIRECTION | RIGHT-HAND SECOND MOUNTING FACILITY |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.750 INCHES NOMINAL SECOND MOUNTING FACILITY |
ABMK | OVERALL WIDTH | 3.090 INCHES MAXIMUM |
ADTV | CASE MATERIAL | PLASTIC |
AEBW | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT | 0.500 INCHES NOMINAL SECOND MOUNTING FACILITY |
AKDX | WINDING QUANTITY | 1 |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
APNP | DUTY TYPE | CONTINUOUS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE SECOND MOUNTING FACILITY |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CBME | CUBIC MEASURE | 45.392 CUBIC INCHES |
CMLP | THREAD QUANTITY PER INCH | 32 SECOND MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR FIRST MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CRXH | TIME DELAY | 5.00 SECONDS MINIMUM ADJUSTABLE OPERATE TIME AND 50.00 SECONDS MAXIMUM ADJUSTABLE OPERATE TIME |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC RESISTIVE LOAD AND 15.0 AMPERES DC RESISTIVE LOAD |
THSD | THREAD SERIES DESIGNATOR | UNC SECOND MOUNTING FACILITY |