Using the Request for Quote (RFQ) form provided on this page, you can request competitive procurement options on part number 669-0152 with rapid responses always offered by our staff. To ensure that you locate and procure exactly what you need with ease, we list parts with as much information as we can. For example, part number 669-0152 It is listed as Transformer Power. component manufactured by Hollingsworth John R Co, specifically under CAGE Code 02032. It is also accompanied by the NSN 5950008407880 for ease of organization, the first digits of the NSN indicating that the part belongs to FSC 5950 Coils and Transformers.
NSN Information for Part Number 669-0152 with NSN 5950-00-840-7880, 5950008407880
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-840-7880 Item Description: Transformer Power | 5950 | 008407880 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
669-0152 | 6 | 9 | 5 |
Characteristics Data of NSN 5950-00-840-7880, 5950008407880
MRC | Criteria | Characteristic |
---|---|---|
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ADAQ | BODY LENGTH | 2.234 INCHES MINIMUM AND 2.266 INCHES MAXIMUM |
ADAT | BODY WIDTH | 1.859 INCHES MINIMUM AND 1.891 INCHES MAXIMUM |
AKNA | INCLOSURE TYPE | OPEN |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 1.2 AMPERES DC NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 4 WIRE LEAD |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAU | BODY HEIGHT | 1.984 INCHES MINIMUM AND 2.016 INCHES MAXIMUM |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 0.922 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 0.954 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES SINGLE GROUP |
CRMJ | WINDING POWER RATING | 1.68 VOLTS-AMPERES SINGLE COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 1.40 DC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |