Using the Request for Quote (RFQ) form provided on this page, you can request competitive procurement options on part number 2200 with rapid responses always offered by our staff. To ensure that you locate and procure exactly what you need with ease, we list parts with as much information as we can. For example, part number 2200 It is listed as Switch Thermostatic. component manufactured by Honeywell International Inc Sen, specifically under CAGE Code 14604. It is also accompanied by the NSN 5930007635974 for ease of organization, the first digits of the NSN indicating that the part belongs to FSC 5930 Switches.
NSN Information for Part Number 2200 with NSN 5930-00-763-5974, 5930007635974
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-763-5974 Item Description: Switch Thermostatic | 5930 | 007635974 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | S | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
2200 | 6 | 2 | 5 |
Characteristics Data of NSN 5930-00-763-5974, 5930007635974
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 1.281 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 0.656 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.109 INCHES NOMINAL |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 0.938 INCHES NOMINAL |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
CSCF | TERMINAL TYPE | TAB, SOLDER LUG |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
CTYX | CONTACT STIMULUS RATING | 190.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 175.00 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT |
MEDA | MEDIA FOR WHICH DESIGNED | GAS |
STYL | STYLE DESIGNATOR | DISC W/FLANGE |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | MOISTURE PROOF |
ABPM | BODY DIAMETER | 0.656 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 0.406 INCHES MAXIMUM |
AKBY | TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
AXGY | MOUNTING METHOD | BRACKET AND UNTHREADED HOLE |
CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
CTHF | CONTACT LOAD CURRENT RATING | 6.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 125.0 DC AT SEA LEVEL SECOND VOLTAGE |
PMLC | PRECIOUS MATERIAL AND LOCATION | CONTACTS SILVER |
PRMT | PRECIOUS MATERIAL | SILVER |