Using the Request for Quote (RFQ) form provided on this page, you can request competitive procurement options on part number 1002-24200-34 with rapid responses always offered by our staff. To ensure that you locate and procure exactly what you need with ease, we list parts with as much information as we can. For example, part number 1002-24200-34 It is listed as Switch Thermostatic. component manufactured by Kysor Industrial Corp, specifically under CAGE Code 75418. It is also accompanied by the NSN 5930005781008 for ease of organization, the first digits of the NSN indicating that the part belongs to FSC 5930 Switches.
NSN Information for Part Number 1002-24200-34 with NSN 5930-00-578-1008, 5930005781008
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-578-1008 Item Description: Switch Thermostatic | 5930 | 005781008 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
1002-24200-34 | C | 2 | 3 |
Characteristics Data of NSN 5930-00-578-1008, 5930005781008
MRC | Criteria | Characteristic |
---|---|---|
AAJD | THREAD CLASS | 2A ALL THREADED STUD |
ADAQ | BODY LENGTH | 2.000 INCHES NOMINAL |
AKBY | TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
AXGY | MOUNTING METHOD | THREADED STUD |
CQJX | NOMINAL THREAD SIZE | 0.375 INCHES ALL THREADED STUD |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, BOTH POSITIONS MAINTAINED |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE, PRESET |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 12.0 DC AT SEA LEVEL FIRST VOLTAGE |
THSD | THREAD SERIES DESIGNATOR | NPT ALL THREADED STUD |
ABHP | OVERALL LENGTH | 4.120 INCHES NOMINAL |
ABPM | BODY DIAMETER | 1.120 INCHES NOMINAL |
ASDB | WIDTH ACROSS FLATS | 1.000 INCHES NOMINAL |
CMLP | THREAD QUANTITY PER INCH | 18 ALL THREADED STUD |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CSCF | TERMINAL TYPE | CONNECTOR, PLUG |
CTHF | CONTACT LOAD CURRENT RATING | 4.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CTYM | CONTACT ADJUSTMENT RANGE | +100.00/+170.00 ACTUATION POINT DEGREES FAHRENHEIT AND +40.00/+175.00 DEACTUATION POINT DEGREES FAHRENHEIT |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL DEACTUATION POINT KNOB AND EXTERNAL ACTUATION POINT KNOB |
CTYX | CONTACT STIMULUS RATING | 30.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
STYL | STYLE DESIGNATOR | CYLINDRICAL W/FLANGE |