Using the Request for Quote (RFQ) form provided on this page, you can request competitive procurement options on part number R310-BKA-3002-BA with rapid responses always offered by our staff. To ensure that you locate and procure exactly what you need with ease, we list parts with as much information as we can. For example, part number R310-BKA-3002-BA It is listed as Relay Electromagnetic. component manufactured by Leach International Corporation, specifically under CAGE Code 58657. It is also accompanied by the NSN 5945012149256 for ease of organization, the first digits of the NSN indicating that the part belongs to FSC 5945 Relays and Solenoids.
NSN Information for Part Number R310-BKA-3002-BA with NSN 5945-01-214-9256, 5945012149256
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-01-214-9256 Item Description: Relay Electromagnetic | 5945 | 012149256 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
R310-Bka-3002-Ba | 5 | 1 | C | A |
Characteristics Data of NSN 5945-01-214-9256, 5945012149256
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 2.500 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 1.600 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 2.152 INCHES MAXIMUM |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.232 INCHES NOMINAL SINGLE MOUNTING FACILITY |
AGAV | END ITEM IDENTIFICATION | CONTROL PANEL |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
APNP | DUTY TYPE | CONTINUOUS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CBME | CUBIC MEASURE | 8.608 CUBIC INCHES |
CQYJ | MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
CRXH | TIME DELAY | 30.00 SECONDS MAXIMUM FIXED OPERATE TIME |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ADTV | CASE MATERIAL | METAL |
ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AKDX | WINDING QUANTITY | 1 |
APCN | COIL QUANTITY | 1 |
APNQ | ARC QUENCHING METHOD | AIR |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC RESISTIVE LOAD AND 10.0 AMPERES DC RESISTIVE LOAD |
TTQY | TERMINAL TYPE AND QUANTITY | 14 WIRE HOOK ALL FUNCTIONS |