Using the Request for Quote (RFQ) form provided on this page, you can request competitive procurement options on part number PS24-0 6A with rapid responses always offered by our staff. To ensure that you locate and procure exactly what you need with ease, we list parts with as much information as we can. For example, part number PS24-0 6A It is listed as Power Supply. component manufactured by Mentor Technologies Inc Dba Mti Div N A, specifically under CAGE Code 0FCY7. It is also accompanied by the NSN 6130010369093 for ease of organization, the first digits of the NSN indicating that the part belongs to FSC 6130 Converters Electrical Non Rotating.
NSN Information for Part Number PS24-0 6A with NSN 6130-01-036-9093, 6130010369093
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-036-9093 Item Description: POWER SUPPLY | 6130 | 010369093 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
PS24-0.6A | 2 | 2 | 3 |
Characteristics Data of NSN 6130-01-036-9093, 6130010369093
MRC | Criteria | Characteristic |
---|---|---|
ABMK | OVERALL WIDTH | 2.500 INCHES NOMINAL |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
APPA | OUTPUT VOLTAGE RATING | 24.0 DC VOLTS NOMINAL SINGLE POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 420.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
BGHX | OUTPUT CONTROL QUANTITY | 1 SINGLE POWER OUTPUT |
CBBL | FEATURES PROVIDED | FILTER |
CWGH | OUTPUT CURRENT RATING | 600.0 DC MILLIAMPERES NOMINAL SINGLE POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 2 SINGLE POWER OUTPUT |
CWHT | INPUT CONNECTION QUANTITY | 2 SINGLE OPERATING POWER RQMT |
ABHP | OVERALL LENGTH | 3.500 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 1.625 INCHES NOMINAL |
ANPM | INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 105.0 AC VOLTS MINIMUM SINGLE OPERATING POWER RQMT AND 125.0 AC VOLTS MAXIMUM SINGLE OPERATING POWER RQMT |
AYNH | OPERATING AMBIENT TEMP RANGE | -20.0/+71.0 DEG CELSIUS |
BGHY | OUTPUT CONTROL TYPE | FIXED VOLTAGE SINGLE POWER OUTPUT |
BHQN | RECTIFICATION METHOD | SINGLE PHASE FULL WAVE BRIDGE |
CWHC | OUTPUT CONTROL LOCATION | FRONT PANEL SINGLE POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP SINGLE POWER OUTPUT |
CWHQ | INPUT CONNECTION TYPE | TERMINAL STRIP SINGLE OPERATING POWER RQMT |
CWKG | VENTILATION DESIGN TYPE | CONVECTION |