Using the Request for Quote (RFQ) form provided on this page, you can request competitive procurement options on part number 2315741P59 with rapid responses always offered by our staff. To ensure that you locate and procure exactly what you need with ease, we list parts with as much information as we can. For example, part number 2315741P59 It is listed as Circuit Breaker. component manufactured by Navair Ltd, specifically under CAGE Code 10001. It is also accompanied by the NSN 5925000131258 for ease of organization, the first digits of the NSN indicating that the part belongs to FSC 5925 Circuit Breakers.
NSN Information for Part Number 2315741P59 with NSN 5925-00-013-1258, 5925000131258
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-00-013-1258 Item Description: Circuit Breaker | 5925 | 000131258 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
2315741p59 | 2 | 1 | 3 |
Characteristics Data of NSN 5925-00-013-1258, 5925000131258
MRC | Criteria | Characteristic |
---|---|---|
ABXD | BUSHING LENGTH | 0.340 INCHES NOMINAL |
ADAQ | BODY LENGTH | 1.531 INCHES NOMINAL |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.875 INCHES NOMINAL |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.855 INCHES NOMINAL |
AKPX | POLE QUANTITY | 2 |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 300.0 AC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CPRW | ACTUATOR FUNCTION | RESET |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.580 MINIMUM AT 200 PCT ALL LOCATIONS AND 6.000 MAXIMUM AT 200 PCT ALL LOCATIONS AND 0.080 MINIMUM AT 300 PCT ALL LOCATIONS AND 1.600 MAXIMUM AT 300 PCT ALL LOCATIONS AND 0.010 MINIMUM AT 400 PCT ALL LOCATIONS AND 0.630 MAXIMUM AT 400 PCT ALL LOCATIONS |
FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
THSD | THREAD SERIES DESIGNATOR | UNEF |
ZZZY | REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | AS DIFFERENTIATED BY SPECIAL TEST FEATURES |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
SPCL | SPECIAL TEST FEATURES | NAVORD OD36190 |
CPRJ | TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 20.0 AMPERES AC ALL LOCATIONS |
CPRP | ULTIMATE TRIP TIME PER POLE IN SECONDS | 2.400 MINIMUM ALL LOCATIONS AND 42.000 MAXIMUM ALL LOCATIONS |
ADTV | CASE MATERIAL | METAL |
AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING W/PANEL SEAL |
ADAT | BODY WIDTH | 1.250 INCHES NOMINAL |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.625 INCHES NOMINAL |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 230.0 AC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | HERMETICALLY SEALED |
CQJX | NOMINAL THREAD SIZE | 0.375 INCHES |
TTQY | TERMINAL TYPE AND QUANTITY | 4 WIRE HOOK |