Using the Request for Quote (RFQ) form provided on this page, you can request competitive procurement options on part number 3146350-7 with rapid responses always offered by our staff. To ensure that you locate and procure exactly what you need with ease, we list parts with as much information as we can. For example, part number 3146350-7 It is listed as Switch Thermostatic. component manufactured by Navair Ltd, specifically under CAGE Code 10001. It is also accompanied by the NSN 5930013510510 for ease of organization, the first digits of the NSN indicating that the part belongs to FSC 5930 Switches.
NSN Information for Part Number 3146350-7 with NSN 5930-01-351-0510, 5930013510510
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-01-351-0510 Item Description: Switch Thermostatic | 5930 | 013510510 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
3146350-7 | 5 | 2 | 3 |
Characteristics Data of NSN 5930-01-351-0510, 5930013510510
MRC | Criteria | Characteristic |
---|---|---|
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | VIBRATION RESISTANT |
ABHP | OVERALL LENGTH | 1.266 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 0.688 INCHES MAXIMUM |
ABTD | MOUNTING SLOT WIDTH | 0.140 INCHES NOMINAL |
ADAU | BODY HEIGHT | 0.626 INCHES NOMINAL |
AWTN | OPERATING TEMP RATING | 0.0 DEG CELSIUS MINIMUM AND 65.0 DEG CELSIUS MAXIMUM |
CBBL | FEATURES PROVIDED | HERMETICALLY SEALED CASE |
CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
CSCF | TERMINAL TYPE | TAB, SOLDER LUG |
CTHF | CONTACT LOAD CURRENT RATING | 2.5 AMPERES RESISTIVE LOAD FIRST VOLTAGE1.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CTYM | CONTACT ADJUSTMENT RANGE | +122.00/+221.00 ACTUATION POINT DEGREES FAHRENHEIT |
CTYX | CONTACT STIMULUS RATING | 176.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
STYL | STYLE DESIGNATOR | DISC W/FLANGE |
ABPM | BODY DIAMETER | 0.750 INCHES MAXIMUM |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.000 INCHES NOMINAL |
AKBY | TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
AXGY | MOUNTING METHOD | BRACKET AND SLOT |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE, PRESET |
CTYS | CONTACT ADJUSTMENT TYPE | INTERNAL ACTUATION POINT SCREW |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE28.0 DC AT SEA LEVEL SECOND VOLTAGE |