Using the Request for Quote (RFQ) form provided on this page, you can request competitive procurement options on part number 3718282-45 with rapid responses always offered by our staff. To ensure that you locate and procure exactly what you need with ease, we list parts with as much information as we can. For example, part number 3718282-45 It is listed as Resistor Variable Nonwire Wound. component manufactured by Other Nsn, specifically under CAGE Code 49671. It is also accompanied by the NSN 5905010211007 for ease of organization, the first digits of the NSN indicating that the part belongs to FSC 5905 Resistors.
NSN Information for Part Number 3718282-45 with NSN 5905-01-021-1007, 5905010211007
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5905-01-021-1007 Item Description: Resistor Variable Nonwire Wound | 5905 | 010211007 | 0 | N | B | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | B | U | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
3718282-45 | 5 | 9 | 5 |
Characteristics Data of NSN 5905-01-021-1007, 5905010211007
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | CYLINDRICAL |
ABJT | TERMINAL LENGTH | 0.188 INCHES MINIMUM |
ABPM | BODY DIAMETER | 0.300 INCHES NOMINAL |
AEFD | ACTUATOR TYPE | FLUSH DRIVE WITH SLOT-HOLE |
CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -100.0/+100.0 SINGLE SECTION |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 0.5 FREE AIR SINGLE SECTION |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -10.0/+10.0 SINGLE SECTION |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 85.0 SINGLE SECTION |
TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN |
AAPN | SECTION QUANTITY | 1 |
ADAQ | BODY LENGTH | 0.250 INCHES NOMINAL |
AYQR | CENTER TO CENTER DISTANCE BETWEEN TERMINAL ROWS | 0.100 INCHES NOMINAL |
APXH | TERMINAL LOCATION | REAR END |
CSDL | STANDARD TAPER CURVE PER SECTION | A SINGLE SECTION |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 1.0 MEGOHMS SINGLE SECTION |
ABHP | OVERALL LENGTH | 0.433 INCHES MINIMUM |
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.100 INCHES NOMINAL |
ADAV | OVERALL DIAMETER | 0.300 INCHES NOMINAL |
AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.200 INCHES NOMINAL |
AXGY | MOUNTING METHOD | TERMINAL |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 150.0 SINGLE SECTION |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |