Using the Request for Quote (RFQ) form provided on this page, you can request competitive procurement options on part number RWR74S37R4FS with rapid responses always offered by our staff. To ensure that you locate and procure exactly what you need with ease, we list parts with as much information as we can. For example, part number RWR74S37R4FS It is listed as Resistor Fixed Wire Wound. component manufactured by Other Nsn, specifically under CAGE Code 81349. It is also accompanied by the NSN 5905012634914 for ease of organization, the first digits of the NSN indicating that the part belongs to FSC 5905 Resistors.
NSN Information for Part Number RWR74S37R4FS with NSN 5905-01-263-4914, 5905012634914
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5905-01-263-4914 Item Description: Resistor Fixed Wire Wound | 5905 | 012634914 | 0 | N | B | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | B | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Rwr74s37r4fs | 5 | 2 | 2 |
Characteristics Data of NSN 5905-01-263-4914, 5905012634914
MRC | Criteria | Characteristic |
---|---|---|
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -20.0 TO 20.0 |
AAPP | ELECTRICAL RESISTANCE | 37.400 OHMS |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -1.000 TO 1.000 |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 275.0 |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0 TO 275.0 |
AARE | REACTANCE CHARACTERISTIC | INDUCTIVE |
AARG | RELIABILITY INDICATOR | ESTABLISHED |
ABPM | BODY DIAMETER | 0.312 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0.875 INCHES NOMINAL |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-39007 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTI |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-39007/6 GOVERNMENT SPECIFICATION |
AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 25.0 |
AAQZ | INCLOSURE METHOD | ENCAPSULATED |
AARB | TERMINAL TYPE | WIRE LEAD |
AARH | RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.001 |
ABJT | TERMINAL LENGTH | 1.500 INCHES MINIMUM |
AEFB | POWER DISSIPATION RATING IN WATTS | 5.000 FREE AIR |
CBME | CUBIC MEASURE | 0.085 CUBIC INCHES |
CBME | CUBIC MEASURE (NON-CORE) | 0.085 CUBIC INCHES |
PKWT | UNPACKAGED UNIT WEIGHT | 5.0 GRAMS |
STYL | STYLE DESIGNATOR | AXIAL TERMINAL EACH END |