Using the Request for Quote (RFQ) form provided on this page, you can request competitive procurement options on part number 1000729-001 with rapid responses always offered by our staff. To ensure that you locate and procure exactly what you need with ease, we list parts with as much information as we can. For example, part number 1000729-001 It is listed as Transformer Power. component manufactured by Rantec Power Systems Inc, specifically under CAGE Code 60132. It is also accompanied by the NSN 5950012608638 for ease of organization, the first digits of the NSN indicating that the part belongs to FSC 5950 Coils and Transformers.
NSN Information for Part Number 1000729-001 with NSN 5950-01-260-8638, 5950012608638
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-260-8638 Item Description: Transformer Power | 5950 | 012608638 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
1000729-001 | 5 | 2 | 3 |
Characteristics Data of NSN 5950-01-260-8638, 5950012608638
MRC | Criteria | Characteristic |
---|---|---|
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.200 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 25.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
ADAQ | BODY LENGTH | 2.250 INCHES NOMINAL |
ADAU | BODY HEIGHT | 1.700 INCHES NOMINAL |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 100.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.300 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAT | BODY WIDTH | 1.600 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT AND 1 TERTIARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 0.2 AMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 2 TURRET AND 16 WIRE LEAD |