Using the Request for Quote (RFQ) form provided on this page, you can request competitive procurement options on part number SE5300-042 with rapid responses always offered by our staff. To ensure that you locate and procure exactly what you need with ease, we list parts with as much information as we can. For example, part number SE5300-042 It is listed as Switch Thermostatic. component manufactured by Robertshaw Controls Co Executive, specifically under CAGE Code 80625. It is also accompanied by the NSN 5930002215070 for ease of organization, the first digits of the NSN indicating that the part belongs to FSC 5930 Switches.
NSN Information for Part Number SE5300-042 with NSN 5930-00-221-5070, 5930002215070
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-221-5070 Item Description: SWITCH,THERMOSTATIC | 5930 | 002215070 | P | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
SE5300-042 | 2 | 2 | 3 |
Characteristics Data of NSN 5930-00-221-5070, 5930002215070
MRC | Criteria | Characteristic |
---|---|---|
ADAQ | BODY LENGTH | 9.250 INCHES NOMINAL |
AFDV | LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 1.750 INCHES NOMINAL |
AKBY | TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE PRESSURE CONNECTION |
CSCF | TERMINAL TYPE | TAB W/SCREW |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE |
CTYM | CONTACT ADJUSTMENT RANGE | +60.00 TO 250.00 ACTUATION POINT DEGREES FAHRENHEIT |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT HEX NUT |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 250.0 AC AT SEA LEVEL SINGLE VOLTAGE |
STYL | STYLE DESIGNATOR | CYLINDRICAL W/FLANGE |
ABPM | BODY DIAMETER | 0.250 INCHES NOMINAL |
AEVT | CAPILLARY TUBE LENGTH | 9.250 INCHES NOMINAL |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE PRESSURE CONNECTION |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
CTHF | CONTACT LOAD CURRENT RATING | 25.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE |
CTYX | CONTACT STIMULUS RATING | 8.00 DIFFERENTIAL POINT NOMINAL DEGREES FAHRENHEIT |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |