Using the Request for Quote (RFQ) form provided on this page, you can request competitive procurement options on part number D1-02-012-01-02 with rapid responses always offered by our staff. To ensure that you locate and procure exactly what you need with ease, we list parts with as much information as we can. For example, part number D1-02-012-01-02 It is listed as Switch Thermostatic. component manufactured by Robertshaw Controls Co New Stant, specifically under CAGE Code 77857. It is also accompanied by the NSN 5930004287506 for ease of organization, the first digits of the NSN indicating that the part belongs to FSC 5930 Switches.
NSN Information for Part Number D1-02-012-01-02 with NSN 5930-00-428-7506, 5930004287506
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-428-7506 Item Description: Switch Thermostatic | 5930 | 004287506 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
D1-02-012-01-02 | 5 | 9 | 5 |
Characteristics Data of NSN 5930-00-428-7506, 5930004287506
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 3.063 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 4.563 INCHES NOMINAL |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.250 INCHES NOMINAL |
AEVT | CAPILLARY TUBE LENGTH | 48.000 INCHES NOMINAL |
AKBY | TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB |
CMLP | THREAD QUANTITY PER INCH | 32 ALL THREADED HOLE |
CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 2 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT KNOB |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
ABMK | OVERALL WIDTH | 1.938 INCHES NOMINAL |
AEVU | BULB LENGTH | 4.500 INCHES NOMINAL |
AEVV | BULB DIAMETER | 0.375 INCHES NOMINAL |
AXGY | MOUNTING METHOD | BRACKET AND THREADED HOLE |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CSCF | TERMINAL TYPE | TAB W/SCREW |
CTHF | CONTACT LOAD CURRENT RATING | 25.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CTYM | CONTACT ADJUSTMENT RANGE | +60.00/+250.00 ACTUATION POINT DEGREES FAHRENHEIT |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 125.0 DC AT SEA LEVEL SECOND VOLTAGE |