Using the Request for Quote (RFQ) form provided on this page, you can request competitive procurement options on part number 674-0005-00REVB with rapid responses always offered by our staff. To ensure that you locate and procure exactly what you need with ease, we list parts with as much information as we can. For example, part number 674-0005-00REVB It is listed as Transformer Power. component manufactured by Rockwell Collins Inc, specifically under CAGE Code 13499. It is also accompanied by the NSN 5950000868728 for ease of organization, the first digits of the NSN indicating that the part belongs to FSC 5950 Coils and Transformers.
NSN Information for Part Number 674-0005-00REVB with NSN 5950-00-086-8728, 5950000868728
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-086-8728 Item Description: Transformer Power | 5950 | 000868728 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
674-0005-00revb | 6 | 1 | C | A |
Characteristics Data of NSN 5950-00-086-8728, 5950000868728
MRC | Criteria | Characteristic |
---|---|---|
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
ADAT | BODY WIDTH | 2.625 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 3.875 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 4.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 6 TURRET |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 3.062 INCHES MAXIMUM |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 2.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |