Using the Request for Quote (RFQ) form provided on this page, you can request competitive procurement options on part number T21-2-1 50A-01-20 with rapid responses always offered by our staff. To ensure that you locate and procure exactly what you need with ease, we list parts with as much information as we can. For example, part number T21-2-1 50A-01-20 It is listed as Circuit Breaker. component manufactured by Sensata Technologies Inc, specifically under CAGE Code 81541. It is also accompanied by the NSN 5925015098741 for ease of organization, the first digits of the NSN indicating that the part belongs to FSC 5925 Circuit Breakers.
NSN Information for Part Number T21-2-1 50A-01-20 with NSN 5925-01-509-8741, 5925015098741
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-509-8741 Item Description: CIRCUIT BREAKER | 5925 | 015098741 | P | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
T21-2-1,50A-01-20 | 5 | 2 | 3 |
Characteristics Data of NSN 5925-01-509-8741, 5925015098741
MRC | Criteria | Characteristic |
---|---|---|
CPRW | ACTUATOR FUNCTION | RESET |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.095 INCHES MINIMUM AND 1.155 INCHES MAXIMUM |
THSD | THREAD SERIES DESIGNATOR | UN |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
CQJX | NOMINAL THREAD SIZE | 0.500 INCHES |
ABXD | BUSHING LENGTH | 0.458 INCHES MINIMUM AND 0.478 INCHES MAXIMUM |
AKPX | POLE QUANTITY | 2 |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC AND 50.0 DC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING |
FREQ | FREQUENCY IN HERTZ | 50.0 OR 60.0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 2 TOGGLE |
TTQY | TERMINAL TYPE AND QUANTITY | 4 TAB, SOLDER LUG |
ADTV | CASE MATERIAL | PLASTIC |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 1.000 MINIMUM AT 200 PCT AND 15.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 200.0 ALL LOCATIONS |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
ADAQ | BODY LENGTH | 1.365 INCHES MINIMUM AND 1.385 INCHES MAXIMUM |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 1.5 AMPERES DC ALL LOCATIONS |
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
CMLP | THREAD QUANTITY PER INCH | 32 |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.090 INCHES NOMINAL |