Using the Request for Quote (RFQ) form provided on this page, you can request competitive procurement options on part number HR42 with rapid responses always offered by our staff. To ensure that you locate and procure exactly what you need with ease, we list parts with as much information as we can. For example, part number HR42 It is listed as Resistor Fixed Wire Wound Nonind. component manufactured by Shallcross Inc, specifically under CAGE Code 54294. It is also accompanied by the NSN 5905002566409 for ease of organization, the first digits of the NSN indicating that the part belongs to FSC 5905 Resistors.
NSN Information for Part Number HR42 with NSN 5905-00-256-6409, 5905002566409
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5905-00-256-6409 Item Description: Resistor Fixed Wire Wound Nonind | 5905 | 002566409 | 0 | N | B | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | B | U | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Hr42 | 2 | 1 | 5 |
Characteristics Data of NSN 5905-00-256-6409, 5905002566409
MRC | Criteria | Characteristic |
---|---|---|
AAPP | ELECTRICAL RESISTANCE | 451.000 OHMS |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -0.100 TO 0.100 |
AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 125.0 |
AAQZ | INCLOSURE METHOD | ENCAPSULATED |
ABJT | TERMINAL LENGTH | 2.000 INCHES MINIMUM |
ADAQ | BODY LENGTH | 0.380 INCHES MAXIMUM |
AEFB | POWER DISSIPATION RATING IN WATTS | 0.100 FREE AIR |
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -15.0/+15.0 |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 145.0 |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -65.0/+145.0 |
AARB | TERMINAL TYPE | WIRE LEAD |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABPM | BODY DIAMETER | 0.130 INCHES MAXIMUM |
CBME | CUBIC MEASURE | 0.005 CUBIC INCHES |
CBME | CUBIC MEASURE (NON-CORE) | 0.005 CUBIC INCHES |
PKWT | UNPACKAGED UNIT WEIGHT | 1.0 GRAMS |
STYL | STYLE DESIGNATOR | AXIAL TERMINAL EACH END |