Using the Request for Quote (RFQ) form provided on this page, you can request competitive procurement options on part number P290-0-0-250 with rapid responses always offered by our staff. To ensure that you locate and procure exactly what you need with ease, we list parts with as much information as we can. For example, part number P290-0-0-250 It is listed as Power Supply. component manufactured by Technipower Llc, specifically under CAGE Code 13850. It is also accompanied by the NSN 6130008785673 for ease of organization, the first digits of the NSN indicating that the part belongs to FSC 6130 Converters Electrical Non Rotating.
NSN Information for Part Number P290-0-0-250 with NSN 6130-00-878-5673, 6130008785673
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-00-878-5673 Item Description: Power Supply | 6130 | 008785673 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
P290-0-0-250 | 2 | 2 | 3 |
Characteristics Data of NSN 6130-00-878-5673, 6130008785673
MRC | Criteria | Characteristic |
---|---|---|
ABKW | OVERALL HEIGHT | 4.813 INCHES MINIMUM AND 4.938 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 6.437 INCHES MINIMUM AND 6.562 INCHES MAXIMUM |
ANPM | INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 105.0 AC VOLTS MINIMUM SINGLE OPERATING POWER RQMT AND 125.0 AC VOLTS MAXIMUM SINGLE OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 50.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 400.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
BHQN | RECTIFICATION METHOD | SINGLE PHASE FULL WAVE CENTER TAP |
CBBL | FEATURES PROVIDED | FILTER |
CWHJ | OUTPUT CONNECTION TYPE | SOLDER LUG SINGLE POWER OUTPUT |
ABHP | OVERALL LENGTH | 6.937 INCHES MINIMUM AND 7.187 INCHES MAXIMUM |
ADZC | ENVIRONMENTAL PROTECTION | HERMETICALLY SEALED |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
APPA | OUTPUT VOLTAGE RATING | 290.0 DC VOLTS NOMINAL SINGLE POWER OUTPUT |
AYNH | OPERATING AMBIENT TEMP RANGE | -20.0/+80.0 DEG CELSIUS |
BGHX | OUTPUT CONTROL QUANTITY | 1 SINGLE POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT SINGLE POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 200.0 DC MILLIAMPERES NOMINAL SINGLE POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 2 SINGLE POWER OUTPUT |