Using the Request for Quote (RFQ) form provided on this page, you can request competitive procurement options on part number P10M-122 with rapid responses always offered by our staff. To ensure that you locate and procure exactly what you need with ease, we list parts with as much information as we can. For example, part number P10M-122 It is listed as Switch Pressure. component manufactured by United Electric Controls Company, specifically under CAGE Code 14314. It is also accompanied by the NSN 5930011164463 for ease of organization, the first digits of the NSN indicating that the part belongs to FSC 5930 Switches.
NSN Information for Part Number P10M-122 with NSN 5930-01-116-4463, 5930011164463
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-01-116-4463 Item Description: Switch Pressure | 5930 | 011164463 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
P10m-122 | 5 | 2 | 5 |
Characteristics Data of NSN 5930-01-116-4463, 5930011164463
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 3.500 INCHES NOMINAL |
AGAV | END ITEM IDENTIFICATION | BLEED AIR SYS |
CMLP | THREAD QUANTITY PER INCH | 20 SINGLE PRESSURE CONNECTION |
CQJB | PROOF PRESSURE | 484.00 POUNDS PER SQUARE INCH GAGE |
CQJX | NOMINAL THREAD SIZE | 0.438 INCHES SINGLE PRESSURE CONNECTION |
CSCF | TERMINAL TYPE | CONNECTOR, RECEPTACLE |
CTZL | PRESSURE CONNECTOR TYPE | FLARED, THREADED EXTERNAL SINGLE CONNECTION |
MEDA | MEDIA FOR WHICH DESIGNED | GAS |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | EXPLOSION PROOF |
ADAV | OVERALL DIAMETER | 1.120 INCHES MAXIMUM |
AJZC | PRESSURE SWITCH TYPE | GAGE |
AWTN | OPERATING TEMP RATING | 65.0 DEG FAHRENHEIT MINIMUM AND 300.0 DEG FAHRENHEIT MAXIMUM |
AXGY | MOUNTING METHOD | INPUT PORT |
CBBL | FEATURES PROVIDED | ELECTRICAL BOX CONNECTOR |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CTHF | CONTACT LOAD CURRENT RATING | 100.0 MILLIAMPERES INDUCTIVE LOAD SINGLE VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
CTYX | CONTACT STIMULUS RATING | 250.00 ACTUATION POINT NOMINAL POUNDS PER SQUARE INCH GAGE AND 200.00 DEACTUATION POINT NOMINAL POUNDS PER SQUARE INCH GAGE AND 50.00 DIFFERENTIAL POINT NOMINAL POUNDS PER SQUARE INCH GAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL SINGLE VOLTAGE |
STYL | STYLE DESIGNATOR | CYLINDRICAL |
THSD | THREAD SERIES DESIGNATOR | UNF SINGLE PRESSURE CONNECTION |